OHA Drinking Water Services
OR41
PWS ID: 93541 ---- CORNER PUB, THE ---- INACTIVE
Archived Chemical Results

Table is loading - please wait...
Pre-2002 data

More Information
How to use this data table
  • Filter: Use the Select Analytes panel below to filter for specific analytes or groups. Note that only analytes for which there are data are listed. Use the dropdown menus in column headers and the Sample Dates box to filter results. Use the Search box to search across all columns. For example, you can enter a specific sample ID, analyte, or any other search criteria into the Search box.
  • Sort: Click column headings to sort ascending or descending. Sort by multiple columns by holding the Shift key while clicking on additional column headings. The arrow in the column heading will show in blue if the results are currently being sorted by that column.
  • Columns: Use the Columns button to select which columns to display in the table, including additional columns not shown in the default display. Drag column headings to rearrange their order.
  • Download: Use the Download button to export data to an Excel or CSV file. Only filtered results will be downloaded.
  • Reset: Click the Reset button to restore default settings.
Abbreviations
  • Analyte Groups:  CEC = Contaminants of Emerging Concern, IOC = Inorganic Chemicals, LCR = Lead & Copper Rule, NO3 = Nitrate, WQ = Water Quality
  • Analyte Levels:  MCL = Maximum contaminant level, ACL = Action level. Analyte level exceedances are indicated with bold red text.
  • ND = Not detected at or above the detection level.
Select Analytes

Sample Dates
From
to
Or select year:
Facility ID Facility Name Source Type Analyte Group Analyte Code Analyte Name
Use the "Select Analytes" panel above to filter.
Sample
Date
Result Analyte
Level
Type
Current
Analyte
Level
Analyte
Level
Units
Detection
Limit
Received
Date
Sample ID Lab ID Lab Name Analysis Method Method Name SelectYear SelectAnalyte SelectResult SelectFacilityID SelectFacilityName SelectSourceType SelectLabID SelectLabName SelectMethod SelectMethodName FilterSampleDate
A WELL Raw IOC 1017 CHLORIDE 7/6/1981 2.7 MCL 250 MG/L 0 7/6/1981 -1885022 1981 IOC-1017 D A WELL Raw 1981-07-06
A WELL Raw LCR 1022 COPPER, FREE 7/6/1981 0.02 ACL 1.3 MG/L 0 7/6/1981 -1885021 1981 LCR-1022 D A WELL Raw 1981-07-06
A WELL Raw IOC 1025 FLUORIDE 7/6/1981 0.8 MCL 4.0 MG/L 0 7/6/1981 -1885024 1981 IOC-1025 D A WELL Raw 1981-07-06
A WELL Raw IOC 1028 IRON 7/6/1981 0.04 MCL 0.3 MG/L 0 7/6/1981 -1885020 1981 IOC-1028 D A WELL Raw 1981-07-06
A WELL Raw CEC 1032 MANGANESE 7/6/1981 ND MCL 0.05 MG/L 0 7/6/1981 -1885019 1981 CEC-1032 N A WELL Raw 1981-07-06
AA WELL Raw NO3 1040 NITRATE 11/30/1998 2.5 MCL 10 MG/L 0.01 12/8/1998 981130BNAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1998 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1998-11-30
A EP for WELL Raw NO3 1040 NITRATE 11/14/1994 3.5 MCL 10 MG/L 0.01 11/29/1994 941114BC*A 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1994 NO3-1040 D A EP for WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1994-11-14
A EP for WELL Raw NO3 1040 NITRATE 10/23/1995 4.8 MCL 10 MG/L 0.01 10/31/1995 951023BC*A 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1995 NO3-1040 D A EP for WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1995-10-23
AA WELL Raw NO3 1040 NITRATE 11/17/1997 3.5 MCL 10 MG/L 0.01 11/26/1997 971117ADAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1997 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1997-11-17
A WELL Raw NO3 1040 NITRATE 7/6/1981 2.1 MCL 10 MG/L 0 7/6/1981 -1885023 1981 NO3-1040 D A WELL Raw 1981-07-06
AA WELL Raw NO3 1040 NITRATE 12/9/1996 3 MCL 10 MG/L 0.01 12/18/1996 961209APAA 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1996 NO3-1040 D AA WELL Raw 11 Coffey Laboratories, Inc. 300 COLORIMETRIC SPADNS, WITH DISTILLATION 1996-12-09
A WELL Raw IOC 1052 SODIUM 7/6/1981 6.2 ACL 20 MG/L 0 7/6/1981 -1885018 1981 IOC-1052 D A WELL Raw 1981-07-06
A WELL Raw WQ 1061 RESIDUE, TOTAL-FIXED 7/6/1981 264 0 7/6/1981 -1885017 1981 WQ-1061 D A WELL Raw 1981-07-06
A WELL Raw IOC 1095 ZINC 7/6/1981 0.04 MCL 5 MG/L 0 7/6/1981 -1885016 1981 IOC-1095 D A WELL Raw 1981-07-06
A WELL Raw WQ 1915 HARDNESS, TOTAL (AS CACO3) 7/6/1981 58 0 7/6/1981 -1885015 1981 WQ-1915 D A WELL Raw 1981-07-06
A WELL Raw WQ 1917 HARDNESS, NONCARBONATE 7/6/1981 46 0 7/6/1981 -1885014 1981 WQ-1917 D A WELL Raw 1981-07-06
A WELL Raw WQ 1925 PH 7/6/1981 5.9 MCL 8.5 PH 0 7/6/1981 -1885012 1981 WQ-1925 D A WELL Raw 1981-07-06
A WELL Raw WQ 1919 CALCIUM 7/6/1981 10 0 7/6/1981 -1885013 1981 WQ-1919 D A WELL Raw 1981-07-06



More information for this water system: SDWIS ID 1361
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA  ::  DW Source Protection
New! Visit our new Drinking Water Source Protection page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List  ::  DW Source Protection

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login