OHA Drinking Water Services
OR41
PWS ID: 91611 ---- GLENWOODS FOOD MART
System Type: NC    Population: 100


Current Open Coliform Sample Schedule
(subject to change based upon future test results)
DIST-A:  1 Routine sample(s)  per Month to be taken beginning 08/01/2023 -

(A begin date of 01/01/1991 indicates the year the Total Coliform Rule was established)

Public water systems that use chlorine or chloramines must measure the residual disinfectant level at the same points in the distribution system and at the same time when total coliforms are sampled.

Repeat, Temporary Routine, and Prior Coliform Sample Schedules
(Schedules in bold reflect current schedules)

GWR:  1 Triggered sample(s) to be taken and reported  02/06/2024 - 02/17/2024
       1 at SRC-BA - WELL
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   02/07/2024 - 02/17/2024  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  09/05/2023 - 09/16/2023
       1 at SRC-BA - WELL
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   09/06/2023 - 09/16/2023  at DIST-A  
-----
TCR:  3 Temporary Routine sample(s) per Month to be taken   06/01/2023 - 06/30/2023  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  05/30/2023 - 06/10/2023
       1 at SRC-BA - WELL
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   05/31/2023 - 06/10/2023  at DIST-A  
-----
TCR:  3 Temporary Routine sample(s) per Month to be taken   05/01/2023 - 05/31/2023  at DIST-A  
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   04/20/2023 - 04/30/2023  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  04/19/2023 - 04/30/2023
       1 at SRC-BA - WELL
-----
TCR:  1 Routine sample(s) per Quarter to be taken   04/01/2023 - 04/30/2023  at DIST-A  
-----
TCR:  3 Temporary Routine sample(s) per Month to be taken   02/01/2023 - 02/28/2023  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   10/01/2020 - 01/31/2023  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  01/04/2023 - 01/15/2023
       1 at SRC-BA - WELL
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   01/05/2023 - 01/15/2023  at DIST-A  
-----
TCR:  1 Routine sample(s) per Month to be taken   11/01/2017 - 03/31/2018  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   07/01/2017 - 10/31/2017  at DIST-A  
-----
TCR:  3 Temporary Routine sample(s) per Month to be taken   04/01/2017 - 04/30/2017  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  03/31/2017 - 04/11/2017
       1 at SRC-BA - WELL
-----
TCR:  3 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   04/01/2017 - 04/11/2017  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   01/01/2016 - 03/31/2017  at DIST-A  
-----
TCR:  5 Temporary Routine sample(s) per Month to be taken   10/01/2015 - 10/31/2015  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   10/01/2014 - 09/30/2015  at DIST-A  
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   09/02/2015 - 09/12/2015  at DIST-A  
-----
GWR:  5 Confirmation sample(s) to be taken and reported  10/22/2014 - 11/03/2014
      
-----
GWR:  1 Assessment sample(s) per Month to be taken   07/01/2014 - 10/31/2014  at SRC-AA  SPRING
-----
TCR:  1 Routine sample(s) per Month to be taken   08/01/2014 - 08/31/2014  at DIST-A  
-----
GWR:  5 Confirmation sample(s) to be taken and reported  07/21/2014 - 08/02/2014
      
-----
TCR:  5 Temporary Routine sample(s) per Month to be taken   07/01/2014 - 07/31/2014  at DIST-A  
-----
TCR:  1 Routine sample(s) per Month to be taken   06/01/2014 - 06/30/2014  at DIST-A  
-----
GWR:  1 Assessment sample(s) Year  01/01/2012 - 06/30/2014  at SRC-AA  SPRING
-----
GWR:  1 Triggered sample(s) to be taken and reported  06/09/2014 - 06/24/2014
       1 at SRC-AA - SPRING
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   06/10/2014 - 06/24/2014  at DIST-A  
-----
TCR:  5 Temporary Routine sample(s) per Month to be taken   04/01/2014 - 04/30/2014  at DIST-A  
-----
TCR:  1 Routine sample(s) per Month to be taken   03/01/2014 - 03/31/2014  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  03/10/2014 - 03/22/2014
       1 at SRC-AA - SPRING
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   03/11/2014 - 03/22/2014  at DIST-A  
-----
TCR:  5 Temporary Routine sample(s) per Month to be taken   01/01/2014 - 01/31/2014  at DIST-A  
-----
TCR:  5 Temporary Routine sample(s) per Month to be taken   12/01/2013 - 12/31/2013  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  12/18/2013 - 12/30/2013
       1 at SRC-AA - SPRING
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   12/19/2013 - 12/30/2013  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  12/18/2013 - 12/30/2013
       1 at SRC-AA - SPRING
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   12/19/2013 - 12/30/2013  at DIST-A  
-----
GWR:  1 Triggered sample(s) to be taken and reported  11/20/2013 - 12/02/2013
       1 at SRC-AA - SPRING
-----
TCR:  4 Repeat sample(s) within 24 hours of a TC+ Routine Sample to be reported   11/21/2013 - 12/02/2013  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   07/01/2003 - 11/30/2013  at DIST-A  
-----
TCR:  1 Routine sample(s) per Quarter to be taken   01/01/1991 - 06/30/2003  at DIST-A  
-----
Hide schedules prior to 2021


Instructions and Notes
  1. If no prior sample schedules appear, then no prior schedules exist within the database.
  2. Schedules for Oregon very small systems might not appear. If the system is active, samples must be collected for the presence of coliform bacteria once per month or once per quarter depending on water type, seasonal operating cycle, or previous sampling results.
  3. If a sample tests positive for total coliform or E. coli, a minimum of 3 repeat samples must be collected. At water systems where quarterly monitoring takes place, 3 routine samples must be collected the month following one in which a routine sample tested positive for the presence of total coliform or E. coli.

    Any time a sample tests positive for the presence of coliform bacteria, the system's operator should contact their regulator. For this water system, that is:
    ODA FOOD SAFETY PROGRAM
    Steve Wong
    (503) 641-2348
    drinkingwater@oda.oregon.gov




More information for this water system: SDWIS ID 2184
System Info  ::  Report for Lenders  ::  Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Contacts & Advisories  ::  Site Visits  ::  Public Notice
Coliform Summary  ::  Coliform Results  ::  Coliform Schedules  ::  LT2  ::  GW/GWUDI Source Details  ::  Plan Review  ::  Annual Fee
Chemical Summary  ::  Chemical Results  ::  Chemical Schedules  ::  Chemical Schedule Summary  ::  Arsenic RAA  ::  Cyanotoxins  ::  PFAS
Lead & Copper  ::  DBP Sample Sites  ::  FANLs  ::  MRDL  ::  GWR 4-Log  ::  Turbidity  ::  SWTR  ::  LRAA  ::  DW Source Protection
New! Visit our new Drinking Water Source Protection page.

Information for all water systems:
Water System Inventory  ::  Water System Surveys  ::  Outstanding Performers  ::  Treatment Plant Inspections  ::  Treatment  ::  Plan Reviews
Alerts  ::  Violations  ::  Compliance & Enforcement  ::  Deficiencies  ::  System Scores  ::  Exceedances  ::  Public Notices  ::  Service Lines
Water Advisories  ::  Contact Reports  ::  Cyanotoxins  ::  PFAS  ::  Post-wildfire VOCs  ::  Fluoride  ::  Certification List  ::  DW Source Protection

Introduction  ::  Data Search Options  ::  Water System Search  ::  DWS Home  ::  DWS Rules

Need help? Email Drinking Water Services for assistance.Staff/Partner Login